Home>>Smoke Alarms
SMOKE ALARM
INSTRUCTION
WELCOME USING
SL81 SMOKE ALARM
The
product adopts ionization room with advanced single-power twin-room structure in
the world, 9V battery as power source, and economizes electricity. It is used in
single room in family. For your safety, you¡¯d better install one alarm in every
room. Please read the instruction carefully before you use it, do not open the
alarm easily to avoid being irregular for working. You cannot replace any
component in this product except for battery to avoid irregular working, if
there is any wrong with it, please contact the supplier promptly.
FUNCTION:
-
The
ionization room adopts single-power twin-room structure in the world, has
high sensitivity and good anti-jamming performance,
-
Adopts
special control CMOS chip gathering high compositive degree, steady
performance and long using life;
-
Tiny power
consumption, battery as power source, safety, convenient installation, not
join other power source,
-
Alarm
function of low voltage, reminding you to replace the battery on time;
-
Periodic
testing: We suggest that you¡¯d better do a simulation testing every week or
every 15 days to guarantee your damage declining to the lowest when danger
happen, you only press the testing button gently for this work;
-
Convenient
installation: Do not effect by the position of power, spare the trouble of
drawing power source, please refer to ¡°installation way and note¡± for the
installation;
-
Double
alarm: Adopts double alarm of sound-audio, it can attend the common or lower
audition user at the same time.
SPECIFICATION:
Power source: DC9V(cascading battery power)
Working current:: surveillant current <10uA,
alarm current <10mA;
Alarm sound: >85dB
Ambient temperature: -10¡æ~50¡æ
Ambient humidity: ¡Ü95%(40¡À2¡æ)
INSTALLATION AND
NOTE:
-
After tryout
for the detector, please replace the battery one time every year, otherwise,
it will effect the working because of the low voltage of battery;
-
There is no
component to replace by yourself except for battery in detector, if there is
any wrong with the product, please contact our service department;
-
Do not place
it at the high humidity, dusty position;
-
You should
install it after the room is decorated; it should be placed in dustproof,
moistureproof, mildewproof position;
-
The detector
should be installed 1.5m away from the blast mouth of air conditioner, there
is no hinder 0.5m in front of detector;
-
The detector
is suitable for level installation, if you want to install slantways, the
degree is less than 45;
-
Having a
test for the detector termly. When testing, please press the testing button,
the buzzer in the detector will chime within 10sec; output the testing
signal at the same time and collect the alarm to emit alarm of sound-audio;
-
If the
detector sound one time every minute, please replace the battery promptly.
The battery should be 9V cascading.
INSTALLATION AND
TESTING:
-
The distance
between installation holes on the base is 80mm; fix two wooden bolts (¦µ3¡Á12)
on the selected position, then push the detector.
-
It will be
sound-audio alarm when electrifying alarm first, stop alarming within 10sec,
then press the testing button after 60sec,if the alarm is sound-audio alarm,
it can be used, if it do not alarm or stop alarming, please contact the
supplier .Do not open your alarm by yourself.
NOTE:
The smoke alarm
cannot be substitute for fire alarm system; it is not sensitive to flammable
gas. We must state that smoke is not secure substitute, at any time it might be
failure; so you must test it periodically and replace it every 5 years. Once
there is accident, we do not undertake any responsibility.