Home>>Smoke Alarms

SE82 Smoke Alarm User¡¯s Manual

SE82 are photoelectric smoke alarms, they are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. SE82 accords with the ISO/DIS 12239 Standard.

IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT. This user¡¯s manual contains important information about your smoke alarm¡¯s operation. To insure your safety, you need install one alarm at least in your every single room. Please don¡¯t open the smoke alarm for that may cause improper effect. If you are installing this smoke alarm for use by others, you must leave this manual ¨Cor a copy of it¡ªwith the end user.

TECHNICAL PARAMETER

                      DC power:power:DC9V
                      Static Current: <10uA
                      Alarm Current:<12mA
                      Low Voltage Alarm: 5.5V~6.2V
                      AC power: power: 110V220V
                      Current:<25 mA
                      Alarm sonority:> 85 db (3m)
                      Working temperature:-10¡æ~40¡æ

WHERE TO INSTALL SMOKE ALARMS

WHERE NOT TO INSTALL SMOKE ALARMS


HOW TO INSTALL THIS SMOKE ALARM

Tools you will need:
*Pencil
*Drill with 6.5mm drill bit
*Standard/Flathead screwdriver
*Hammer

TEST

It is important to test this unit weekly to make sure it is working properly. Don¡¯t open the alarms by yourself, return them to the seller if improperly, and don¡¯t use fire to test your alarms.

REGULAR MAINTENANCE

Carbon zinc:EVEREADY 216 OR 2122;GOLDPEAK 1604P OR 1604S

Alkaline:EVEREADY 522 DURACELL MN1604 MS1604;GOLDPEAK 1604A

Lithium: ULTRALIFE U9VL

LIMITATIONS OF SMOKE ALARMS

HOW TO DO IN CASE OF FIRE